1-4 Setting the Dip Switches
1-4-1 Serial Interface
• DIP Switch 1
SW
Function
ON
OFF
Default
1-1
Auto Cutter Selection
Disable
Enable
OFF
1-2
Flow Control
XON/XOFF
DTR/DSR
OFF
1-3
Data Length
7 bits
8 bits
OFF
1-4
Parity Check
Yes
No
OFF
1-5
Parity Selection
EVEN
ODD
OFF
1-6
Baud rate Selection (bps)
Refer to the following Table 1
OFF
1-7
ON
1-8
OFF
• Table 1 – Baud rate (bps) Selection
Transmission Speed
1-6
1-7
1-8
Default
2400
ON
OFF
OFF
9600
4800
ON
OFF
ON
9600
OFF
ON
OFF
19200
OFF
OFF
OFF
38400
OFF
ON
ON
57600
OFF
OFF
ON
115200
ON
ON
ON
1-4-2 Parallel / Ethernet Interface
• DIP Switch 1
SW
Function
ON
OFF
Default
1-1
Auto Cutter Selection
Disable
Enable
OFF
1-2
Reserved
-
-
OFF
1-3
Reserved
-
-
OFF
1-4
Reserved
-
-
OFF
1-5
Reserved
-
-
OFF
1-6
Reserved
-
-
OFF
1-7
Reserved
-
-
ON
1-8
Reserved
-
-
OFF