BIXOLON SRP-352plus Especificações Página 120

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 136
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 119
SRP-350/352plusII
Rev. 1.01 BIXOLON
- 120 -
- If an unrecoverable error (bit 5) occurs, turn off the power as soon as possible.
Third byte (paper sensor information)
Bit
Off/On
Hex
Decimal
Function
0,1
Off
00
0
Paper near end sensor: paper adequate
On
03
3
Paper near end sensor: paper near end
2,3
Off
00
0
Paper end sensor: paper present
On
0C
12
Paper end sensor: no paper present
4
Off
00
0
Not used. Fixed to Off
5
Off
00
0
Not used. Fixed to Off
6
Off
00
0
Not used. Fixed to Off
7
Off
00
0
Not used. Fixed to Off
Fourth byte (paper sensor information)
Bit
Off/On
Hex
Decimal
Function
0
On
01
1
Not used. Fixed to On
1
On
02
2
Not used. Fixed to On
2
On
04
4
Not used. Fixed to On
3
On
08
8
Not used. Fixed to On
4
Off
00
0
Not used. Fixed to Off
5
Off
00
0
Not used. Fixed to Off
6
Off
00
0
Not used. Fixed to Off
7
Off
00
0
Not used. Fixed to Off