Rev. 1.03
- 16 -
SPP-R200
MSR Setting value
Hex. Function
30 Track 1/2 read mode command
31 Track 2/3 read mode command
32 Track 1 read mode AUTO trigger
33 Track 2 read mode AUTO trigger
34 Track 1/2 read mode AUTO trigger
35 Track 2 read mode AUTO trigger
36 Track 3 read mode AUTO trigger
37 Track 2/3 read mode AUTO trigger
38 MSR not used
EOT
[Name]
[Format]
[Description]
Cancel card read mode
ASCII EOT
Hex 04
Decimal 4
▪ Cancel card read mode
▪ Works the same as when the POWER button is pressed
ESC R n
[Name]
[Format]
[Range]
[Default]
[Description]
Select an international character set.
ASCII ESC R n
Hex 1B 52 n
Decimal 27 82 n
0 ≤ n ≤ 13
n=0
▪ Selects international character set in from the following table :
n Character set n Character set
0 U.S.A 7 Spain I
1 France 9 Norway
2 Germany 10 Denmark II
3 U.K
4 Denmark I
5 Sweden
6 Italy