Rev. 1.03
- 31 -
SPP-R200
<Function 11> GS ( E pL pH fn a d1….dk (fn=11)
[Format]
[Range]
[Default]
[Description]
ASCII GS ( E pL pH fn a d1 dk
Hex 1D 28 45 pL pH 0B a d1 dk
Decimal 29 40 69 pL pH 11 a d1 dk
3<=(pL + pH x 256) <=8 (3<=pL<=8,0<= pH<=255)
fn=11, 1<=a ≤ 4
48<=d<=57 [a=1]
48<=d<=50 [a=2]
d=48,49 [a=3]
d=55,56 [a=4]
1<=k<=6
d1..dk=”19200” [a=1]
d=48[a=2]
d=48[a=3]
d=56[a=4]
sets the configuration item for the serial interface specified by a to the values
specified by d1..dk
a Configuration item
1 Transmission speed
2 Parity
3 Flow control
4 Data length
Transmission speed (a=1) is specified by number.
Example : When defining 19200 bps : 5bytes d1…dk “19200”(Hexadecimal =
31H,39H,32H,30H,30H
/Decimal= 49,57,50,48,48)
Parity (a=2) is specified by d as follows
d Function
48 Select no parity
49 Select odd parity
50 Select even parity
Flow control(a=3) is specified by d as follows
d Function
48 Select Flow control DTR/DSR
49 Select Flow control XON/XOFF
Data Length(a=4) is specified by d as follows
d Function
55 Select 7bit length
56 Select 8bit length