SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 124 -
After the [Header-NULL] is transmitted, the printer receives a response from the host; then it performs the process
defined by the response. (See the tables below.)
- When the status (existence of the next data block) is Hexadecimal = 41H / Decimal = 65
Response
Process performed
ASCII
Decimal
ACK
6
Transmits the next data.
NAK
21
Transmits the previous data again.
CAN
24
Ends the process.
- When the status (for the last data block) is
Hexadecimal = 40H / 40H/Decimal = 64
Response
Process performed
ASCII
Decimal
ACK
6
Ends the process.
NAK
21
Transmits the previous data again.
CAN
24
Cancels the process.
Remarks:
None
Differences:
None