SPP-R210 Command Manual
Rev. 1.00 BIXOLON
- 7 -
n=2: Off-line status
Bit
Off/On
Hex
Decimal
Status
0
Off
00
0
Fixed
1
On
02
2
Fixed
2
Off
00
0
Cover is closed
On
04
4
Cover is open
3
Off
00
0
Paper is not being fed by using the paper FEED button
On
08
8
Paper is being fed by the paper FEED button
4
On
10
16
Fixed
5
Off
00
0
No paper-end stop
On
20
32
Printing is being stopped
6
Off
00
0
Fixed
7
Off
00
0
Fixed
n=3: Error status
Bit
Binary
Hex
Decimal
Status
0
0
00
0
Not used. Fixed to Off
1
1
02
2
Not used. Fixed to On
2
0
00
0
Not used. Fixed to Off
3
0
00
0
Not used. Fixed to Off
4
1
10
16
Not used. Fixed to On
5
0
00
0
Not used. Fixed to Off
6
0
00
0
Not used. Fixed to Off
7
0
00
0
Not used. Fixed to Off