Remarks:
The horizontal and vertical starting positions are out of the printable area, this command is canceled and the following
data is processed as normal data.
If (Horizontal starting position + Horizontal printing area width) is beyond the printable area, the Horizontal printing
area width is set to (Horizontal printing area - Horizontal starting position).
If (Vertical starting position + Vertical printing area width) is beyond the printable area, the Vertical printing area width
is set to (Vertical printing area - Vertical starting position).
This command is not effective in standard mode. If this command is processed in standard mode, the setting by this
command is effective when the printer returns to page mode.
The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
Differences:
The maximum printable area(Max horizontal printable area, Max vertical printable area):
Model
Max horizontal printable area
Max vertical printable area
SRP-350plusIII
72.2mm(512dots)
234.3mm(1662dots)
SRP-352plusIII
72mm(576dots)
207.75mm(1662dots)