BIXOLON SRP-352plusIII Manual do Utilizador Página 77

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 120
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 76
SRP-350/352plusIII
Rev. 1.00 BIXOLON
- 77 -
<Function 066> GS ( k pL pH cn fn n (fn=66)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
42
n
Decimal
29
40
107
3
0
48
66
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48, fn=66
n=0, 3 ≤ n ≤ 90
Default:
n = 0
Description:
This command specifies the number of rows in the data area of PDF417.
When n=0, automatic processing is set
When n is not 0, the number of rows is set to n rows.
Remarks:
Settings of this function affect the processing of Functions 081.
With auto processing (n=0) specified, the maximum number of rows is set to 90.
With auto processing (n=0) specified, the number of rows is calculated by using the following information:
Printing area when processing Functions 081
Module height (Function 068)
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None
Vista de página 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 119 120

Comentários a estes Manuais

Sem comentários