SRP-F310/312
Rev. 1.00 BIXOLON
- 114 -
GS I
Function: Transmits printer ID
Code:
ASCII
GS I n
Hex
1D 49 n
Decimal
29 73 n
Range:
1 ≤ n ≤ 69
Default:
None
Description:
■ This command transmits the printer ID or information.
• Transmits 1 byte of printer ID, using n as follows:
n Printer ID Specification
1,49 Printer model ID Printer model
2,50 Type ID Printer type
3,51 Printer feature ID Printing method and Printer size
• Transmits specified printer information, using n as follows:
n Printer ID type Specification
65 Firmware version Firmware version
66 Manufacturer BIXOLON
67 Printer model Printer model
69 Code page Currently enabled code page
Remarks:
■ Printer information (When n = 65, 66, 67, 69) consist of [Header ~ NULL] data as shown below:
Transmitted data Hex Decimal Amount of data
Header 5FH 95 1byte
Printer information Depends on the model Depends on the model 0-15 bytes
NUL 00H 0 1byte
■ The firmware version can be confirmed by self test printing.