SRP-F310/312
Rev. 1.00 BIXOLON
- 94 -
<Function 070> GS ( k pL pH cn fn m (fn=70)
Code:
ASCII
GS ( k pL pH cn fn m
Hex
1D 28 6B 03 00 30 46 m
Decimal
29 40 107 3 0 48 70 m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=70
m=0,1
Default:
m = 0
Description:
This command selects the option for PDF417.
m Function
0 Select the standard PDF417
1 Select the simplified PDF417
Remarks:
Settings of this function affect the processing of Functions 081 and 082.
When simplified PDF417 symbol is canceled, standard PDF417 symbol is automatically selected.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None