BIXOLON SRP-352plusA&C Manual do Utilizador Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 54
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
Rev. 1.03
- 4 -
SRP-350/352plusA&C
2. Control Commands Details
2-1 Command Notation
[Name]
[Format]
[Range]
[Description]
The name of the command.
The code sequence. ASCII Indicates the ASCII equivalents.
Hex indicates the hexadecimal equivalents.
Decimal indicates the decimal equivalents.
[ ] k indicates the contents of the [ ] should be repeated k times.
Gives the allowable ranges for the arguments.
Describes the function of the command.
2-2 Explanation of Terms
LSB Least Significant Bit
2-3 Control Commands Details
HT
[Name]
[Format]
[Description]
Horizontal tab.
ASCII HT
Hex 09
Decimal 9
Moves the print position to the next horizontal tab position.
LF
[Name]
[Format]
[Description]
Print and line feed.
ASCII LF
Hex 0A
Decimal 10
In standard mode, prints the data in the print buffer and feeds one line
based on the current line spacing.
In page mode, modes the print position in memory to feed one line based
on the current line spacing.
FF
[Name]
[Format]
[Description]
Print and return to standard mode in page mode.
ASCII FF
Hex 0C
Decimal 12
In page mode, prints the data in the print buffer collectively and returns to
standard mode.