SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 106 -
<Function 51> GS ( L pL pH m fn (fn=3, 51)
Code:
ASCII
GS ( L pL pH m fn
Hex
1D 28 4C pL pH m fn
Decimal
29 40 76 pL pH m fn
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
m=48, fn=3, 51
Default:
None
Description:
▪ Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 31H 49 1 byte
Data 30H – 39H 48 - 57 1 - 8 bytes
NUL 00H 0 1 byte
■ The number of bytes of remaining memory is converted to character codes corresponding to decimal data, then
transmitted from the MSB.
■ The data length is variable.
Remarks:
Differences:
None