SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 90 -
<Function 3> GS ( E pL pH fn [a1 b18...b11]...[ak bk8...bk1] (fn=3)
Code:
ASCII
GS ( E pL pH fn [b18...b11]... [bk8...bk1]
Hex
1D 28 45 pL pH fn [b18...b11]... [bk8...bk1]
Decimal
29 40 69 pL pH fn [b18...b11]... [bk8...bk1]
Range:
10 ≤ (pL + pH x 256) ≤ 65535
fn=3
a= 1, 2, 5, 6, 7, 8
b=48, 49, 50
1 ≤ k ≤ 10
Default:
It varies depending on the printer model
Description:
■ This command changes all the Memory Switch(Msw) 1 through 8 to the value specified by b simultaneously as
follows:
• When b=48, 49, the corresponding bit is set to Off and On respectively.
• When b=50, there is no change in the memory switch.
■
The setting items of the memory switch 1 are as follows:
Value
Msw
3 2 1
Function
48 48 48 Print density 130%
48 48 49 Print density 120%
48 49 48 Print density 110%
48 49 49 Print density 150%
49 48 48 Print density 100%
49 48 49 Print density 140%
49 49 48 Print density 90%
1-1~3
49 49 49 Print density 80%
Comentários a estes Manuais