SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 129 -
GS h
Function: Selects bar code height
Code:
ASCII
GS h n
Hex
1D 68 n
Decimal
29 104 n
Range:
1 ≤ n ≤ 255
Default:
n=162
Description:
This command sets the height of the bar code to n dots.
Remarks:
■ The unit of n depends on the printer model.
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
■ Unit of one dot: 0.125mm(1/203 inch)