SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 148 -
BS M S PL PH fn4 m
Function Transmit Start and End characters setting information
Code:
ASCII
BS M S pL pH fn4 m
Hex
08 4D 53 pL pH 34 m
Decimal
08 77 83 pL pH 52 m
Range:
(pL+pHx256) = 2
fn = 50
m = 49, 50, 51
Default:
None
Description:
■ m defines the track to be transmitted.
■ The transmission format is as follows:
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 81H 129 1 byte
Track 31H~33H 49~51 1byte
Start characters 20H ~ 7FH 32~127 Max 10 bytes
Separate 1F 31 1byte
End characters 20H~7FH 32~127 Max 10 bytes
NUL 00H 0 1 byte
■ The track on the above table indicates the track information of transmission data.
■ For example, the track value of 31H indicates the information on the Start and End characters of Track 1.
■ If d is set to Null 1-byte in fn3, End characters are not transmitted.
Remarks:
None