SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 83 -
<Function 367> GS ( k pL pH cn n (fn=67)
Code:
ASCII
GS ( k pL pH cn fn n
Hex
1D 28 6B 03 00 33 43 n
Decimal
29 40 107 3 0 51 67 n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=51
fn=67
2 ≤ n ≤ 3
Default:
n=3
Description:
This command sets the DATAMATRIX Code size.
Remarks:
■ This command affects the execution of <Function 381>.
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
■ Since the DATAMATRIX Code module is square, n = module width = module height.
Differences:
None