<Function 1> GS ( F pL pH m a nL nH (m=1)
Code:
ASCII
GS ( F pL pH m a nL nH
Hex
1D 28 46 04 00 01 a nL nH
Decimal
29 40 70 4 0 1 a nL nH
Range:
(pL + pH × 256) = 4 (pL = 4, pH = 0)
m = 1
a = 0, 48
0 ≤ (nL + nH × 256) ≤ 65535 (0 ≤ nL ≤ 255, 0 ≤ nH ≤ 255)
Default:
nL = 0, nH = 0
Description:
■ This command sets the value for the adjustment of print starting position after sensing BM.
• pL, pH specifies (pL + pH × 256) as the number of bytes after pH (m, a, nL, and nH)
• nL, nH specifies [(nL + nH × 256) × vertical motion units] as the adjustment value.
Remarks:
■ This command affects to the execution of the command FF.
■ This command is only effective for the forward paper feeding.
■ The maximum adjustable length is 400 mm. If the adjustment value to be specified exceeds the maximum value, the
adjustment value is automatically set to the maximum value.